As long as the switch provides a contact closure it can be wired into the system and then in software can have as many functions as you want it to. The maximum number of Extension on the Loxone Link is 30.Īlongside the Loxone Touch and Touch Pure switches you can also make any conventional switches become much more useful and multi-functional.Our recommendation is a pair of a CAT7 cable between panels and a twisted pair of panel wire within the cabinet. The Link must be a single twisted pair.The Link has to be terminated at the last device with a 120 Ohm resistor if no Extensions are used then no resistor should be used.The Loxone link MUST be a BUS strictly wired from one device to the next. If you use multiple panels and as such have many Extensions around the project, then the maximum allowable length of the Loxone Link is 500m from the Miniserver to the last extension.Wire back to a central point for non-Tree products.In the below diagrams you can see some examples of wiring Loxone Tree. True future-proof wiring for the Smart Home. This can reduce cabling up o 80% over traditional STAR wired systems and gives huge flexibility in upgrading and updating in the future. If this Tree “network” is at some point connected back to the Tree Extension ALL Tree devices will then be connected. In essence, any Tree device can be connected to any other in order to get its control and communication. This enables the wiring to be done in a much more efficient and flexible way. When considering sensors and switches (and indeed heating actuators) these can be wired using the Loxone Tree technology in tandem with the Tree cable. Outputs such as lighting circuits and control for blinds are centrally wired in a STAR pattern where each device has it’s own cable coming back to the central location. Typically on a Loxone system there is a centrally mounted “panel” that contains all of the Loxone equipment as such this becomes the hub (or node 0) of the installation. Please note that it cannot be used for 230V loads! For load switching you will have to use appropriately rated power cables, i.e. A CAT7 cable can be used for various applications, Tree communications, PC Networks, volt free contacts, serial communication, bus systems, and more. In general there are 4 main types of cable that are used for a Loxone system:įor the sensor side, which is low voltage we recommend you use CAT7 cable. We therefore recommend that you use cables that have stood the test of time and have become industry standards. The wiring is the backbone of an automation system and whilst it is easy to replace a motion sensor, a switch or a light fitting it is much harder to replace the cables that are plastered into your walls. It is therefore important to think ahead and future proof your installation. No one knows where this journey is taking us and there will be lots of new switches, sensors, light-fittings and much more to come. Whilst nature has perfected its signalling system over thousands of years, home automation has only been around for a few decades. The wiring in your home can be compared to the nervous system in a human body, without it the automation system can neither sense nor act.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |